What is the fire resistance rating of lightweight partition panel
Source:DQ Date:2017/4/10 9:20:32
As the country, for the
promotion of new wall materials of lightweight partition panel as can take the
place of red bricks, aerated block of new wall materials has been used in the factory, such as residential, office buildings,
hospitals, public use on the project. So widely used what is the fire resistance rating of
lightweight partition panel, can meet the demand of various types of
refractory? Lightweight partition panel experts of Daquan group to analysis a
fire resistance rating issued Daquan lightweight partition panel.
1、The division of building fire resistance rating
Architectural fireproof rank division is one of the most
basic measures of building fire protection technology measures, China's
architectural design specification of the building fire resistance rating is
divided into one, two, three, four, the highest level is ONE, refractory
strongest ability; The weakest level is FOUR, refractory ability.
2、Fire resistance rating is determined by what
The building's fire resistance rating depends on the composition
of the combustion performance of the construction of the building and fire
resistance. Construction refers to the walls of the building, foundation, beam,
column, floor, stair, condole top, and a series of basic composition components.
3、Combustion performance levels
Combustion performance is divided into four levels: A level,
otherwise; B1 level, flame retardant; B2, flammability; B3 level, flammability.
Daquan lightweight partition panel as wall important component parts of the
building, combustion performance is very high to ensure the fire safety of
buildings, Daquan lightweight partition board combustion performance is A level.
4、Fire resistance rating
In the standard fire test conditions, the structure of
building components, accessories, or from the role of the fire, when he took
the insulating losing stability, integrity, or stays during this period,
expressed in hours. The fire resistance of construction requirements, see the
table below.
Can be seen from the table, the highest refractory
requirement is 3 hours, that of the Daquan fire resistance can achieve many of
lightweight partition panel, the first to show that a fire resistance test
report issued Daquan lightweight partition panel.
Daquan lightweight partition panel pass national fire
protection agency test, fireproof limit to 4 hours, beyond the building wall
fire prevention requirements 3 hours, both factories, homes, hospitals, office
buildings, public buildings, the wall can be rest assured use of Daquan lightweight
partition panel. If you also need to know more about the content of Daquan
lightweight partition board, welcome total-free hotline: 400-027-1215.